Voltage covers: 2V
Capacity: From 200Ah to 3000Ah
Designed floating service life: @ 20 oC/68 oF 20 years.
The LSG range of gel technology batteries offers outstanding performance including a 18+ years design life. The LSG batteries is designed based on the LSE series, using the polymer gel electrolyte. Built to the highest standards and compliant with the latest IEC60896- 21/ 22 standard. this range also offers 100% capacity out- of- the- box and is capable of handling deep discharges for complete peace of mind. The use of flexible connectors and the ability to be installed both horizontally and vertically allows for multiple installation possibilities.
|
| Code |
Nominal
Voltage
(V) |
Capacity
(AH) |
Dimension |
Weight |
Terminal |
| Length |
Width |
Height |
Total Height |
Kg |
Lb |
Type |
Position |
| mm |
in |
mm |
in |
mm |
in |
mm |
in |
| LSG2-50 |
2 |
50
|
161 |
6.34 |
50 |
1.97 |
166 |
6.54 |
166 |
6.54 |
3.1 |
6.84 |
T17 |
G |
| LSG2-100 |
2 |
100
|
171 |
6.73 |
72 |
2.84 |
205 |
8.07 |
221 |
8.66 |
6.2 |
13.7 |
T22 |
G |
| LSG2-150 |
2 |
150
|
172 |
6.77 |
102 |
4.02 |
206 |
8.11 |
221 |
8.70 |
8.7 |
19.2 |
T22 |
G |
| LSG2-200A |
2 |
200
|
94.5 |
3.72 |
184.5 |
7.26 |
360.5 |
14.2 |
372 |
14.6 |
14.5 |
32.0 |
T22 |
G |
| LSG2-200 |
2 |
200
|
173 |
6.81 |
109 |
4.29 |
330 |
13.0 |
365 |
14.4 |
13.5 |
29.8 |
T22 |
G |
| LSG2-250 |
2 |
250
|
173 |
6.81 |
109 |
4.29 |
330 |
13.0 |
365 |
14.4 |
15.4 |
34.0 |
T22 |
G |
| LSG2-260 |
2 |
260
|
109 |
4.29 |
184.5 |
7.26 |
360.5 |
14.2 |
372 |
14.6 |
17.4 |
38.4 |
T22 |
G |
| LSG2-300 |
2 |
300
|
123 |
4.84 |
184.5 |
7.26 |
360.5 |
14.2 |
372 |
14.6 |
19.4 |
42.8 |
T22 |
G |
| LSG2-400 |
2 |
400
|
166 |
6.54 |
184.5 |
7.26 |
360.5 |
14.2 |
372 |
14.6 |
26.5 |
58.4 |
T22 |
G |
| LSG2-500 |
2 |
500
|
194.5 |
7.66 |
184.5 |
7.26 |
360.5 |
14.2 |
372 |
14.6 |
31.3 |
69.0 |
T22 |
G |
| LSG2-600 |
2 |
600
|
223 |
8.78 |
184.5 |
7.26 |
360.5 |
14.2 |
372 |
14.6 |
37.5 |
82.7 |
T22 |
H |
| LSG2-800 |
2 |
800
|
154 |
6.06 |
229 |
9.02 |
555 |
21.9 |
566 |
22.3 |
52.7 |
116 |
T22 |
H |
| LSG2-800A |
2 |
800
|
280 |
11.0 |
186 |
7.32 |
306.5 |
14.2 |
372 |
14.6 |
47.7 |
105 |
T22 |
H |
| LSG2-1000 |
2 |
1000
|
186 |
7.32 |
229 |
9.02 |
555 |
21.9 |
566 |
22.3 |
62.8 |
138 |
T22 |
H |
| LSG2-1000A |
2 |
1000
|
339 |
13.3 |
190 |
7.48 |
360.5 |
14.2 |
372 |
14.6 |
58.8 |
130 |
T22 |
H |
| LSG2-1200 |
2 |
1200
|
225 |
8.86 |
229 |
9.02 |
555 |
21.9 |
566 |
22.3 |
75.5 |
166 |
T22 |
H |
| LSG2-1500 |
2 |
1500
|
265.5 |
10.5 |
229 |
9.02 |
555 |
21.9 |
566 |
22.3 |
93 |
205 |
T22 |
G |
| LSG2-2000 |
2 |
2000
|
349 |
13.7 |
233 |
9.17 |
555 |
21.9 |
566 |
22.3 |
122 |
269 |
T22 |
I |
| LSG2-3000 |
2 |
3000
|
496 |
19.5 |
363 |
14.3 |
362 |
14.3 |
374 |
14.7 |
176 |
388 |
T22 |
K |
Features
- Sealed and maintenance free operation.
- Non-Spillable construction design.
- ABS containers and covers(UL94HB, UL94V-0) optional.
- Safety valve installation for explosion proof.
- High quality and high reliability.
- Exceptional deep discharge recovery performance.
- Low self discharge characteristic.
- Flexibility design for multiple install positions.
|
Application
- Correspondence exchange and transmission system
- Mobile communication system
- Power plant and power transformer system
- Radio and broadcasting station
- Navigation and signaling system
- Emergency power system
- UPS
- Other spare, circulatory system
|
|